Mitsumi electronic QS07J1GF11-T2 Drums User Manual


 
204
(c) REQ instruction (clock data read) setting
The following program is for the setting of REQ instruction (clock data read).
Control data
Request data
Device Item Set value
(S1)+0 D270 Abnormal end type
0091
H
(Sets data for abnormal end)
(S1)+1 D271 Completion status
(Setting is not required because it is set by the
system.)
(S1)+2 D272 Channels used by own station 2
(S1)+3 D273 Target station's CPU type
0000
H
(control CPU)
(S1)+4 D274 Target station's network No. 1
(S1)+5 D275 Target station number 2
(S1)+6 D276 (Unused) 0
(S1)+7 D277 Number of resends 5 times
(S1)+8 D278 Arrival monitoring time 0 (10 seconds)
(S1)+9 D279 Request data length 2 (clock data read)
(S1)+10 D280 Response data length
(Setting is not required because it is set by the
system.)
(S1)+11 D281 Clock set flag
(S1)+12 to
(S1)+15
D282 to D285 Clock data of abnormal end
(S1)+16 D286
Error-detected station's network
No.
(S1)+17 D287 Error-detected station number
Device Item Set value
(S2)+0 D290 Request type
0001
H
(clock data read)
(S2)+1 D291 Sub-request type
0002
H
(clock data read)