CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.6 JP/GP.WRITE (Writing Data to the Programmable Controller on Another Station)
When failed
(3) Error
When the dedicated instruction fails, error details can be checked by any of the following methods:
(a) In GX Developer
Error details can be checked using CC-Link IE Field Network diagnostics. ( Page 124, CHAPTER 9)
(b) By devices
Completion status indication device ((D2)+1) is turned on and an error code is stored in Completion status
((S1)+1) of the control data.
According to the error code, check the error details and take a corrective action.
( Page 246, Section 12.5)
1 scan
3000
WRITE
Sequence scan
Start contact
Own station CPU
Master/local module
Completion device
(Device specified in (D2))
Completion status indication
device (Device of (D2)+1)
Write data storage device
(Device specified in (S2))
Error code
Completion status
(Device of (S1)+1)
END0 END0
Channel 1
Target station error
END0 END0 END0
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF