4.7.2.12. HOLDOFF Feature
The DAS HOLDOFF feature allows to prevent data collection during calibrations and
during the DAS_HOLDOFF period enabled and specified in the VARS (Section 4.12).
To enable or disable the
HOLDOFF for any one DAS channel, follow the instruction
shown in section 6.7.2.2 then press:
Edit Data Channel Menu
SETUP X.X 0) CONC: ATIMER, 2, 900
PREV NEXT INS DEL EDIT PRNT EXIT
Exits to the main
Data Acquisition
menu
SETUP X.X NAME:CONC
<SET SET> EDIT PRINT EXIT
SETUP X.X CAL HOLD OFF:ON
SET> EDIT PRINT EXIT
ENTR accepts the new
setting and returns to the
previous menu.
EXIT ignores the new setting
and returns to the previous
menu.
SETUP X.X CAL HOLD OFF:ON
ON ENTR EXIT
Toggle button to turn
HOLDOFF ON or OFF
Press SET> key until…
From the DATA ACQUISITION menu
(see Section 6.7.2.2)
07270B DCN6512