10s Hold
1 Press the [./10s HOLD] key to display .
The 10s place of the program number will be held
(xed).
2 Now you can press any numeric key [0][9] to input the
1s place of the program number with a single keystroke.
3 You can use the [ ] [ ] keys to change the value of the
10s place.
4 To cancel, press the [./10s HOLD] key to turn off the
display.
(Tempo) [040...240, EXT]
This sets the tempo of the arpeggiator. The tempo can also
be adjusted by the ARPEGGIATOR [TEMPO] knob.
A display of EXT indicates that the MIDI Clock (Global
P1: 11a) setting has been set to External MIDI or External
mLAN, and that the arpeggiator will synchronize to MIDI
Clock messages received from an external MIDI device.
01b: Program Information
This displays the functions that are assigned to the [SW1]
and [SW2] keys and to the B mode of REALTIME CON-
TROL knobs [1], [2], [3], [4], and the names of the effects that
are selected for the insertion effects and the master effects.
01c: Performance Editor
The Performance Editor lets you edit major program param-
eters without moving to the Program P1P9 Edit pages.
This allows you to adjust multiple program parameters
within the currently selected program simultaneously, so
you can make broad adjustments quickly and easily.
You can use the Performance Editor when you wish to
adjust the depth of effects while you are playing, or to make
the initial rough settings to begin the process of creating a
new sound.
If you wish to keep the results of your editing, you must
write (save) the program (BG p.56).
Editing done using the Performance Editor will occur
within the range of the corresponding parameter. If
after using the Performance Editor to modify a value,
you move to another page or mode and then return, the
sound will remain in its edited state but the value
shown in the LCD screen by the Performance Editor
will be +00. You may do further editing from this state
if you wish.
Since editing done using the Performance Editor is not
as detailed as conventional editing, the balance
between parameters may be lost. If this occurs, use P1
P9 Edit page to make ne adjustments.
If the Enable Exclusive (Global P1: 11b) setting is
checked, MIDI exclusive parameter changes will be
transmitted whenever you operate the Performance
Editor. If these messages are received by a TRITON
STUDIO whose Enable Exclusive setting is checked,
the Performance Editor corresponding to that message
will be modied.
Octave [03...+00...+03]
An adjustment of +01 will raise the pitch one octave.
An adjustment of 01 will lower the pitch one octave.
However, this setting cannot adjust the pitch higher than 4'
(feet) or lower than 32' (feet).
Pitch Stretch [12...+00...+12]
This simultaneously adjusts the Transpose and Tune of the
oscillator. This lets you produce a variety of tonal changes
and variations without loosing the character of the original
sound.
At the +00 setting, the value of the program parameters will
be unchanged.
An adjustment of +01 will lower the Transpose value by 1,
and simultaneously raise the Tune value by 100.
An adjustment of 01 will raise the Transpose value by 1,
and simultaneously lower the Tune value by 100.
However, it is not possible for the Transpose value to exceed
the range of ±12, nor the Tune value to exceed the range of
±1200.
This Performance Editor function cannot be used with
bank INT-F.
OSC Balance [10...0...+10]
This adjusts the level balance between oscillators 1 and 2.
At the +00 setting, the value of the program parameters will
be unchanged.
Positive (+) settings will lower the oscillator 2 level.
With an adjustment of +10, the oscillator 2 level will be 0.
The oscillator 1 level will not change.
Negative () settings will lower the oscillator 1 level.
With an adjustment of 10, the oscillator 1 level will be 0.
The oscillator 2 level will not change.
For programs whose Oscillator Mode (11a) setting
is Single, oscillator 2 will not sound. Only the level of
oscillator 1 will change. For a Drums program, this per-
formance editor will have no effect.
Amp Level [10...0...+10]
This adjusts the amp level.
With an adjustment of +00, the value of the program param-
eters will be unchanged.
Positive (+) settings will increase the amp level above the
value that was set.
With an adjustment of +10, the amp level will be 127 (maxi-
mum).
Negative () settings will lower the amp level below the
value that was set.
With an adjustment of 10, the amp level will be 0.
Attack Time [10...0...+10]
This adjusts the attack times of the lter EG and amp EG.
With an adjustment of +00, the value of the program param-
eters will be unchanged.
Positive (+) settings will lengthen the attack times beyond
the values that were set.
With an adjustment of +10, the attack times will be 90.
Negative () settings will shorten the attack times.
With an adjustment of 10, the attack times will be 0.
When you modify Attack Time, the EG Start Level,
Attack Level, Start Level Modulation, and Attack Time
Modulation of the amp EG will also be adjusted simul-
taneously, to allow the maximum effect to be obtained.
Decay Time [10...0...+10]
This adjusts the Decay Time and Slope Time of the lter EG
and amp EG.
With an adjustment of +00, the value of the program param-
eters will be unchanged.
Positive (+) settings will lengthen the Decay Time and Slope
Time beyond the values that were set. With an adjustment of
+10, the times will be 99.
Negative () settings will shorten the Decay Time and Slope
Time. With an adjustment of 10, the times will be 0.