Korg Triton Studio Electronic Keyboard User Manual


 
158
If data of the specied bank is completely absent from
the .PCG le, an error of No readable data will be dis-
played, and the load operation will be halted.
If the program data of the specied bank is not found in
the .PCG le, the program banks of the combination or
multi timbres/tracks will not be set.
If the user arpeggio patterns of the specied bank are
not found in the .PCG le, the user arpeggio pattern
numbers of combinations, programs (/Song) will not
be set .
If the drum kits of the specied bank are not found in
the .PCG le, the drum kit number of the programs will
not be set.
If you specify banks I-C/I-D/I-E when loading a TRI-
TON, TRITON-Rack or TRITON STUDIO .PCG le,
drum kits and user arpeggio patterns will not be
loaded.
If you use All to load a .PCG le from the TRITON/
TRITONpro/TRITONproX, the following dialog box
will appear if that .PCG le contains either Drumkit
Bank C/Bank D/Bank User or User Arpeggio Pattern
Bank C/Bank D. In this dialog box you can specify the
loading destination for each bank. Only banks existing
in the .PCG le are valid. Unless you check the box of a
valid bank, that bank will not be loaded. Press the OK
button to execute loading, or press the Cancel button
to cancel without loading.
3 If Load ****** .SNG too is checked, you can use
Select .SNG Allocation to specify how song data within
the .SNG le will be loaded.
Append: The multi data will be loaded starting at the
number that follows the last song data in memory. The
song data within the .SNG le that is being loaded will
be packed into the available locations (See the follow-
ing diagram). Select this method when you wish to load
song data from disk without erasing the song data that is
already in memory.
Cue list data will not be loaded.
Clear: Erases all cue list data and song data from internal
memory, and load the cue list data together with the state
of the song data as it was when saved (See the follow-
ing diagram). Select this when you want to reproduce the
saved state immediately after power-on, etc.
4 .KSC Allocation is valid if Load
********
.KSC too
has been checked. You can specify how the multisamples
and samples in the .KSC le will be loaded.
Append: Samples will be loaded starting at the rst
unoccupied number following the last multisample or
sample that currently exists in memory (i.e., by having
been sampled or loaded). At this time, only the valid
multisamples or samples will be loaded, and they will be
organized in numerical order. (See the following dia-
gram)
At the same time, programs within the .PCG le that use
multisamples from the .KSC le will automatically have
the multisample settings for their oscillators rewritten so
that each program uses the correct multisample. Drum
kits in the .PCG le that use samples from the .KSC le
will automatically have the sample settings for the drum
kit rewritten so that the drum kit uses the correct sam-
ples.
Clear: All multisamples and samples currently in mem-
ory will be erased, and the multisamples and samples
will be loaded in the same conguration in which they
were saved. (See the following diagram)
If memory already contains multisamples or samples
that you wish to keep, and you wish to load additional
multisamples or samples from disk, select Append.
If the power has just been turned on, or you want to
reproduce the state that was saved, select Clear.
5 To load the data, press the OK button. To cancel without
loading, press the Cancel button.
2) Load Programs: selected icon
All program data from a .PCG le will be loaded.
1 To load the data, press the OK button. To cancel without
loading, press the Cancel button.
SNG000
SNG001
SNG005
SNG003
SNG000
SNG002
SNG003
SNG000
SNG002
SNG005
SNG003
SNG000
SNG001
SNG005
SNG003
SNG004
SNG007
SNG006
SNG000
SNG001
SNG005
SNG003
SNG000
SNG002
SNG003
Append
Clear
.SNG Allocation
.SNG file to load Internal memory of
the TRITON STUDIO
before loading
Internal memory of
the TRITON STUDIO
after loading
KSC000
KSC001
KSC005
KSC003
KSC000
KSC002
KSC003
KSC000
KSC002
KSC005
KSC003
KSC000
KSC001
KSC005
KSC003
KSC004
KSC007
KSC006
KSC000
KSC001
KSC005
KSC003
KSC000
KSC002
KSC003
Append
Clear
.KSC Allocation
.KSC file to be loaded
Internal memory of
the TRITON STUDIO
before loading
Internal memory of
the TRITON STUDIO
after loading