Korg musical instruments Musical Instrument User Manual


 
Loading data from disk Loading individual banks from a .PCG file
173
Loading individual banks from a .PCG file
1. Select the .PCG le containing the data you want
to load, and choose the page menu command
“Load Selected.”
Refer to steps 1–4 of “Loading .PCG, .SNG, and .KSC
files” on page 171.” Select the .PCG file in step 5.
2. Press the page menu button to open the page
menu, and choose “Load Selected.”
You can load individual banks by using “.PCG
Contents” in the dialog box to select the load-source
bank, and “To” to select the load-destination bank.
When you execute loading, only the programs,
combinations, drum kits, and wave sequence data of
the selected bank will be loaded into the load-
destination bank you specify. Global setting data will
not be loaded.
If you set “.PCG Contents” to Bank INT-A, and “To” to
Bank INT-A, data will be loaded as follows.
Programs
• Bank INT-A: loaded into Bank INT-A
Combinations
• Bank INT-A: loaded into Bank INT-A
Drum Kits
• INT: loaded into Bank INT
Wave Sequences
• INT: loaded into Bank INT
When data is loaded into a bank that is different than
its original bank, the data (bank, program, pattern, and
kit numbers, etc.) will automatically be reconfigured so
that after loading, the various types of data will
correspond correctly in each mode.
The following data will also be reconfigured
automatically if you have checked “Load .SNG too”
(so that song data is loaded at the same time), the
following data will also be reconfigured automatically
in order to ensure that the song data plays back
correctly.
The bank of each program used by combinations
The bank of each drum kit and wave sequence used
by each program
The bank of the program used by each track of the
song
If the song contains track/pattern events, the
program banks within these events
Loading data by individual item or bank
The OASYS lets you load programs, combinations,
drum kits, and wave sequences individually or by
individual banks.
This is a convenient way to rearrange combinations in
the order in which you will use them during a live
performance.
Be aware that if you change the order of programs,
the sounds played by combinations may also be
affected.
As an example here, we will explain how a
combination saved in bank INT-D can be loaded into
INT-E000.
1. Move to the “Bank INT-D” directory, and select
the combination that you want to load. (.PCG
le/Combinations/Bank INT-D/)
The procedure is as follows.
1) Perform steps 1–5 under “Loading .PCG, .SNG,
and .KSC files” on page 171. Select the .PCG file
containing the data you want to load (it will be
highlighted), and press the Open button.
2) Press “Combinations” to highlight it, and press
the Open button.
3) Press “Bank D” to highlight it, and press the
Open button.
4) Press the scroll bar to find the combination you
want to load, and highlight it in the display.
Alternatively, you could select any file, since the
desired file can be selected later from the dialog box.