Other disk operations Restoring the factory settings
179
Restoring program, combination, drum
kit, wave sequence, and global settings to
their factory-set condition
This section explains how to restore these settings to
their factory-set condition. This is done by loading the
PRELOAD.PCG file (provided on the included CD and
on the internal hard disk). Here we will explain the
method of loading the PRELOAD.PCG file from the
included CD.
Before you load this data, you must access the
Global mode P0: Basic Setup– Basic page, and un-
check the “Memory Protect” setting for the data you
are going to load. If you execute this operation with
this setting checked, a message of “Memory
Protected” will appear, and the data will not be
loaded.
When you load a .PCG file, the internal memory of
the OASYS will be overwritten by the data of the
.PCG file (programs, combinations, drum kits, wave
sequences, and global settings). If you want to keep
the contents of internal memory, you must use Save
All or Save PCG to save your data before you
execute the following procedure.
1. Insert the included CD “Restore 1/4” into the
OASYS’s CD-R/RW drive.
2. Press the MODE DISK switch to enter Disk mode,
and press the LCD screen to make the OASYS
recognize the disc.
3. Press the File tab and then the Load tab to select
the Disk– Load page.
The LCD screen will show the file information.
4. Use Drive Select to select CDD.
5. Select the PRELOAD.PCG le.
The selected file will be highlighted.
6. Select the page menu command “Load selected.”
The following dialog box will appear.
The displayed dialog box and the settings will depend
on the type of file you’re loading.
7. Use “.PCG Contents” to specify the data you want
to load. To completely restore the factory voicing,
use the All setting.
If you use the All setting to load PRELOAD.PCG from
the included CD, all data of the .PCG file will be
loaded as follows.
Programs
Bank INT-A file: loaded into Bank INT-A (HD-1)
Bank INT-B file: loaded into Bank INT-B (HD-1)
Bank INT-C file: loaded into Bank INT-C (HD-1)
Bank INT-D file: loaded into Bank INT-D (HD-1)
Bank INT-E file: loaded into Bank INT-E (HD-1)
Bank INT-F file: loaded into Bank INT-F (EXi)
Bank USER-A file: loaded into Bank USER-A (HD-
1)
Bank USER-F file: loaded into Bank USER-F (EXi)
Combinations
Bank INT-A file: loaded into Bank INT-A
Bank INT-B file: loaded into Bank INT-B
Bank INT-C file: loaded into Bank INT-C
Drum Kits (40 Drum Kits)
Bank INT file: loaded into Bank INT
Wave Sequences (150 Wave Sequences)
Bank INT file: loaded into Bank INT
8. Press the OK button to load the data.
Never attempt to remove the media while data is