Korg D32XD Recording Equipment User Manual


 
110
6. LOW G/F/Q
[–15 dB…+15 dB/21 Hz…20 kHz/0.1…10, Shlv]
Here you can adjust the gain, center frequency, and Q (fil-
ter sharpness) of the low-frequency region.
If you select Shlv as the Q value, this will become a shelv-
ing-type EQ; in this case the F value will be the cutoff fre-
quency.
7. LOW-MID G/F/Q
[–15 dB…+15 dB/21 Hz…20 kHz/0.1…10]
Here you can adjust the gain, center frequency, and Q (fil-
ter sharpness) of the low-mid frequency region.
8. HIGH-MID G/F/Q
[–15 dB…+15 dB/21 Hz…20 kHz/0.1…10]
Here you can adjust the gain, center frequency, and Q (fil-
ter sharpness) of the high-mid frequency region.
9. HIGH G/F/Q
[–15 dB…+15 dB/21 Hz…20 kHz/0.1…10, Shlv]
Here you can adjust the gain, center frequency, and Q (fil-
ter sharpness) of the high-frequency region.
If you select Shlv as the Q value, this will become a shelv-
ing-type EQ; in this case the F value will be the cutoff fre-
quency.
10.FLAT
Sets the Gain of each equalizer band to 0 dB. The EQ set-
tings for that channel will be initialized.
11.ON/OFF
Switches the equalizer on/off. This allows you to listen to
the signal with and without EQ quickly to check your set-
tings.
12. buttons
Use these up/down buttons to edit the parameter values.
3d-2. EQ Library
Here you can load EQ settings from an EQ library. You can
also store EQ settings in a user EQ library.
There are 50 preset EQ libraries, and 50 user EQ libraries.
An EQ library stores parameters 6–9 of the preceding section
“3d-1. EQ.”
1. EQ library list
Press the screen to select an EQ library. The list shows the
library number (P** are presets, U** are user) and library
name.
2. CH [1…16]
Press a CH SELECT (or the edit cell) to select the channel
into which you will load an EQ library or whose EQ set-
tings you will store in an EQ library.
This channel is linked with “CH” of the “EQ/ATT” tab
page.
3. EQ curve graph
The EQ curve of the selected library is shown as a graph.
4. Recall
Loads the selected library into the channel you selected
in 2. “CH.”
Use the library list to select the library that you want to
load.
Press the button to display the Recall dialog box, verify
the library and the loading-destination channel, and
press the Yes button. If you decide not to load, press the
No button.
5. Store
This stores the EQ settings of the “EQ/ATT” tab page into
one of the user EQ libraries.
The EQ settings of the channel selected by 2.”CH” will be
stored.
A name will automatically be assigned to the stored
library.
The PlayEQ of channel 8: CH08-I.EQ
The RecEQ of channel 10: CH10-EQ
Verify the store-destination number and press the Yes
button. If you decide not to store, press the No button.
5a. Rename
You can press this button to edit the name of the
library program (p.97).
5b. Program number cell
Here you can select the store-destination program
number. Press the cell to highlight it, and use the
value dial (or the +/– keys) to make your selection.
3d-3. Phase
You can invert the phase of each channel.
If an audio device is input in stereo via a jack whose hot and
cold conductors are reversed, their stereo position may be
blurred, or portions of the sound may be cancelled. This set-
ting lets you invert the phase to correct such situations.
4
1
2
3
5
5a
5b
1