Mitsubishi Electronics QD75MH2 Drums User Manual


 
Appendix - 30
MELSEC-Q
APPENDICES
Appendix 3.2 Wiring of SSCNET cables
Generally use the SSCNET
cables available as our options. If the required length is
not found in our options, fabricate the cable on the customer side.
(1) Explanation of shape name
The figure of the length column of the cable in the table is a sign that enters
part of the cable type name. The cable of length with the sign is prepared.
Table 1 SSCNET cable list
Cable length
Cable model
name
0.15m
(0.49ft.)
0.3m
(0.98ft.)
0.5m
(1.64ft.)
1m
(3.28ft.)
3m
(9.84ft.)
5m
(16.40ft.)
10m
(32.81ft.)
20m
(65.62ft.)
30m
(98.43ft.)
40m
(131.23ft.)
50m
(164.04ft.)
Winding
Longevity
Usage and
remarks
MR-J3BUSM 015 03 05 1 3 Standard
Standard
code use in
board
MR-J3BUS
M-A 5 10 20 Standard
Standard
outside board
cable use
MR-J3BUSM-B 30 40 50
High
winding
Long
distance cable
use
: Please inquire of our company about the cable of less than 30m.
(2) Specification
Table 2 Cable specification
Content
SSCNET Cable model name MR-J3BUS
M MR-J3BUS
M-A MR-J3BUS
M-B
SSCNET Cable length [m] ([ft.])
0.15
(0.49)
0.3 to 3
(0.98 to 9.84)
5 to 20
(16.4 to 65.62)
30 to 50
(98.43 to 164.04)
Minimum bend radius
[mm] ([inch])
25(0.98)
Reinforcement film cable
: 50(1.97)
Code part : 25(0.98)
Reinforcement film cable
: 50(1.97)
Code part : 30(1.18)
The maximum tension [N] 70 140
420
(Reinforcement film cable)
980
(Reinforcement film cable)
Category temperature range
[°C] ([°F])
- 40 to 80(- 40 to 176) - 20 to 70(- 4 to 158)
Atmosphere
indoor (Direct sunshine must not strike.)
Neither solvent nor oil must adhere.
Optical
cable
(code)
Externals [mm] ([inch])
2.2 0.07
(0.087)
4.4 0.1
(0.173)
2.2 0.07
(0.087)
7.6 0.1
2.2 0.07
(0.087)
4.4 0.1
(0.173)
(0.299)
7.6 0.5
2.2 0.2
(0.087)
4.4 0.4
(0.173)
(0.299)
: It is a value in optical cable (code) unit.