Mitsubishi Electronics QD75MH2 Drums User Manual


 
3 - 24
MELSEC-Q
3 SPECIFICATIONS AND FUNCTIONS
(2) Example when using the forced stop of the QD75MH and MR-J3-B
CP3
QY41PQD75MHQnCPU
Q61P-A2
CP1
CP2
A
CN1A
CN1B
DICOM
ALM
EM1
DOCOM
0
SM
U
V
W
Servomotor
Ground
Electromagnetic
breake
2
Ra3
Ra3
MR-J3-B
Servo amplifer
U
V
W
L1
L2
L3
L11
L21
SSCNET
EMI.
COM EMI
COM
3-phase
200VAC to
230VAC
NFB
MC
Ra1
Alarm
1
Forced stop Operation ready
OFF ON
MC
MC
SK
Alarm
24VDC
Powerr
supply
24VDC
24GDC
Forced stop
SSCNET
24VDC
6
B
CN1A
CN1B
DICOM
ALM
EM1
DOCOM
1
SM
U
V
W
Servomotor
Ground
Electromagnetic
breake
2
Ra4
MR-J3-B
Servo amplifer
U
V
W
L1
L2
L3
L11
L21
6
C
CN1A
CN1B
DICOM
ALM
EM1
DOCOM
2
SM
U
V
W
Servomotor
Ground
Electromagnetic
breake
2
Ra5
MR-J3-B
Servo amplifer
U
V
W
L1
L2
L3
L11
L21
6
Ra2
24VDC
Ra2
24VDC
Ra2
Ra4
Ra5
Ra2
Ra1
1: Configure up the power supply circuit which switch off the electromagnetic contactor (MC) after detection alarm occurrence on the PLC
CPU.
2: The power supply for the electromagnetic brake is possible to use a full wave rectified power supply.
3: When turning off the control power supply of servo amplifier, communication with servo amplifier is not possible from then on.
Example) If turning off the control power supply of servo amplifier L11/L21 in the above figure
B
, communication with the servo
amplifier of
C
cannot be performed either. For turning off power supply of certain servo amplifier, turn off the main circuit
power L1/L2/L3, but do not turn off the control power supply L11/L21.
4: When changing servo amplifier, turn off both the main circuit power L1/L2/L3 and the control power supply L11/L21. As communication
between servo amplifier and QD75MH is not possible at this time, stop the machine operation in advance and then change servo
amplifier.
5: The dynamic brake is operated, and servomotor occurs to the free run when EM1 (forced stop) of servo amplifier turn OFF. At the time,
the display shows the servo forced stop warning (E6).
During ordinary operation, do not used forced stop signal to alternate stop and run.
The service life of the servo amplifier may be shortened.
6: If setting servo amplifier to Axis 1, set the rotary axis setting switch of servo amplifier to "0".
Set "Axis2 => 1 for rotary switch", "Axis3 => 2 for rotary switch" and "Axis4 => 3 for rotary switch" respectively.