Comparisons of performance specifications (Continued)
Model
Item
QD75MH1 QD75MH2 QD75MH4 QD75M1 QD75M2 QD75M4
CHG signal
External command signal (External start or speed-position switching selectable with
parameters)
In-position (INP)
(for monitor)
I/O signal for
external devices
Signal logic switching
Connection with peripheral
devices
Connection via PLC CPU,
Q Corresponding Serial Communication Module, Q Corresponding MELSEC/H Remote
I/O Module
AD71TU
AD75TU
A6GPP, A6PHP
A7GPP, A7PHP
PC-9800
R
series
Peripheral devices
(data setting, etc.)
DOS/V personal computer
: Possible, : Not possible
1: Up to 100 data items/axis of positioning data (No. 1 to 100) can be set using the buffer memory. The positioning data in the buffer
memory is not backed up.
2: Indicates the INC mode/ABS mode in speed-position switching control.
3: When "Speed control 10 x multiplier setting for degree axis function" is valid, this will be the setting range 0.01 to 20000000.00
(degree/min).
4: The near pass function is valid only during the continuous path control.
(2) Function comparisons
Functions added to those of QD75M1/QD75M2/QD75M4
Added functions Remarks
Forced stop function Refer to Section 12.4.5
Speed control 10 x multiplier setting for degree axis function Refer to Section 12.7.11
Operation setting for incompletion of OPR function Refer to Section 12.7.12
External signal selection function Refer to Section 13.4
External I/O signal logic switching function Refer to Section 13.5