1. Recording Samples (Sampling)
234 RS7000
[STANDBY/START/STOP] → [F4] or [STANDBY/START/STOP]
→ [STANDBY/START/STOP]
From this display sampling will begin according to the following
conditions:
• If TRIGGER MODE = LEVEL … Sampling will begin auto-
matically as soon as the input signal exceeds the specified trig-
ger level.
• If TRIGGER MODE = MEASURE … Press [STANDBY/
START/STOP] after pressing [PLAY] from the Sampling
Standby page to start sequence playback. Sampling will begin
automatically at the specified punch-in measure.
The Sampling Execution Page will appear when sampling begins.
This display appears during sampling.
From this display sampling will end according to the following
conditions:
• If TRIGGER MODE = MANUAL or LEVEL … Sampling
will end as soon as the [STANDBY/START/STOP] button is
pressed. If sequencer playback started automatically when
sampling was started, pressing the [STOP] button to stop play-
back will also end sampling. Sampling will also end if the pat-
tern or sequence plays all the way through to the end and stops
automatically.
• If TRIGGER MODE = MEASURE … Sampling will end auto-
matically when the specified punch-out measure is reached. Or
sampling will end if the [STANDBY/START/STOP] button is
pressed.
The Trim page will appear when sampling ends and the SLICE +
SEQ sampling type is selected.
The trim function makes it possible to specify the beginning and
end points of a measure within a sample to allow appropriate slic-
ing. Data prior to the specified beginning of the measure and data
after the specified end of the measure will be deleted, thus reduc-
ing the overall data size.
The Trim page is automatically selected after sampling when the
SLICE+SEQ sample type is selected.
1
NORMALIZE......................................................... [Knob 1]
[Settings] OFF, ON
OFF...................No normalization.
ON.....................The sample will be normalized.
Normalization achieves the highest possible sample level by
finding the highest level in the target sample and increasing
the overall sample level so that the peak level is just below
clipping. This function is used to increase the sound quality
of recorded samples.
NOTE
When the TRIGGER MODE is set to MANUAL
sampling will begin as soon as the [STANDBY/
START/STOP] button is pressed.
Sampling Execution Page
Trim Page
NOTE
To ensure proper slicing the sample should be
trimmed so that it loops cleanly. Loop playback
begins when the [F2] (AUDITION) button is
pressed, making it easy to hear even slight
changes in the sample length.
NOTE
Since slicing divides a sample into multiple seg-
ments, normalization while maintaining the
overall level relationship between the divided
samples is not possible after slicing. When nor-
malization is necessary it should be applied
before slicing.
7
5
34216
[Knob 2] [Knob 3]
[Knob 4]
[Knob 1]
[F2]
[F4]
Normalize