Tektronix VX4101A Drums User Manual


 
SCPI Commands for the Digital Multimeter
3–238
VX4101A MultiPaq Instrument User Manual
NOTE. If the test fails, you can obtain further information on the failure with the
SYST:ERR? query.
Command Response
INSTRUMENT:SELECT DIGO Select the Digital Output
TEST:ALL? “Digital Output passes self test.”
Run self test.
READ? Subsystem
The READ queries enable you to initiate and acquire a measurement.
N/A
READ?
N/A
N/A
MEASure?
CONFigure
SENSe
INPUt
INITiate
FETCh?
N/A
READ?
The READ? query is a sub-level command of the measurement subsystem, as its
action is dependent on the configuration set up by the higher level MEASure,
CONFigure, and SENSe commands. It performs a measurement acquisition by
executing an INITiate:IMMediate command, followed by a FETCh? query. The
measurement function which is performed is based on the current configuration
set up by the higher level commands. For example, if a CONFig-
ure:ARRay:VOLTage:DC? 10,3.0 command was previously issued, a READ?
query would initiate, acquire, and return 10 DC V measurements in the 3.0 V
Examples
Command Syntax
Query Syntax
*RST Value
Limits
Related Commands
Command Description
Query Response