Installation
1–16
VX4101A MultiPaq Instrument User Manual
NOTE. If the VX4101A is inserted in a slot with any empty slots to the left of the
module, the VME daisy-chain jumpers must be installed on the backplane in
order for the VXI Module to operate properly. Check the manual of the main-
frame being used for instructions on jumper settings. If the jumpers are not
installed properly, there will be no interrupts and bus masters will not operate
properly. Jumpers are not necessary for auto-configuring backplane designs
such as those in Tektronix mainframes.
Follow these steps to install the VX4101A:
CAUTION. The VX4101A Module is a piece of electronic equipment and therefore
has some susceptibility to electrostatic damage (ESD). ESD precautions must be
taken whenever the module is handled.
1. Record the revision levels, serial numbers (located on the label on the top
shield of the VX4101A), and switch settings on the Installation Checklist.
2. Verify that the switches are set to the correct values. Refer to Controls and
Indicators for more information on setting switches.
3. Make sure that the mainframe power is Off.
4. Insert the module into one of the instrument slots of the mainframe (see
Figure 1–3).
Figure 1–3: Module Installation
Module Installation
Procedure