Tektronix VX4101A Drums User Manual


 
SCPI Commands for the SurePatht Modules
3–278
VX4101A MultiPaq Instrument User Manual
After this, each time the VXI TTL trigger 2 is pulsed low, the following
sequence of events occurs:
1. One second delay. This is the delay specified in the trigger:Sequence:delay
command.
2. The current relay in the scan list is opened.
3. 0.5 second delay. This is the delay specified in the route:open:dwell
command.
4. Close the next relay in the scan list.
5. 0.25 second delay. This is the delay specified in the route:close:dwell
command.
6. Pulse VXI TTL trigger 1 low for 200 ns.
7. Wait 5 ms then pulse the front panel encode signals corresponding to the
section of the close relay. The encode signals are pulsed low for 4 ms.
[ROUTe:]CLOSe:MODE
Three additional VX4330 Modules are installed in consecutive slots to the right
of this module.
Command Response
route:close:mode mux
m1,(1:6)
Set all six sections of the first VX4330 to mux mode
route:conf twire,m1,(1:6) Configure all six sections of the first VX4330 to 20-to-1 2-wire
scanner/mux
route:close (@m1(1!1:10!1)) Close the first 10 relays in section one of the first VX4330
route:close:mode
scan,m3,(1:3)
Set the close mode of sections 1 through 3 of the third VX4330
to “scan”
route:conf:join m3,(1:3) Join the commons of sections 1 through 3 of the third VX4330
route:conf owire,m3,(1:3) Set the configuration of sections 1 through 3 of the third
VX4330 to 40 to 1 one wire
NOTE: The previous three commands configure sections 1 through 3 of the third VX4330 as a
120-to-1 1-wire VX4330. The 1-wire common of any of these sections can be used as the
120-to-1 1-wire common.
close (@m3(1!1)) Open all channels in sections 1 through 3 of the third VX4330,
then close channel 1 of section 1.
close? (@m3(1!1:40!3)) 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0