Tektronix VX4101A Drums User Manual


 
SCPI Commands for the SurePatht Modules
VX4101A MultiPaq Instrument User Manual
3–281
Command Response
route:open:all m2 Open all relays on the VX4380
route:close (@m3(1!6)) Close relay number 1 in section 6 of the VX4330
route:close (@m4(3!1:3!8)) Close relay number 3 in all eight sections of the VX4320
[ROUTe:]MODule:CATalog?
A VX4380 and VX4330 are installed in consecutive slots to the right of the slot
containing the VX4350.
Command Response
route:module:catalog? “M1”, “M2”, “M3”
route:module:define matrix_
1,2
Assign module name “matrix_1” to the VX4380
route:module:catalog? “M1”, “MATRIX_1”, “M3”
route:module:define? matrix_1 2
route:module:delete matrix_1 Delete module name “matrix_1”
route:module:catalog? “M1”, “M3”
[ROUTe:]MODule:CATalog:SUPPorted?
This query returns a list of SurePatht modules that are supported in this version
of firmware.
Command Action Returns
inst:sel SurePath
Selects the SurePathtmas-
ter
rout:mod:cat:supp?
Returns SurePatht module
supported.
VX4320, VX4330, VX4350,
VX4351, and VX4380
[ROUTe:]MODule[:DEFine]
A VX4380 and VX4330 are installed in consecutive slots to the right of the slot
containing the VX4350.
Command Response
route:module:define
gp_switch,1
Assign module name “gp_switch” to the VX4350
route:close
(@gp_switch(1:64))
Close all 64 relays on the VX4350