Tektronix VX4101A Drums User Manual


 
Using the Counter
2–30
VX4101A MultiPaq Instrument User Manual
Measuring Time Interval with Delay
1. Select the Counter:
INST:SEL COUNTER
2. Set input 1 coupling to DC:
INPut:COUPling DC
3. Set input 1 impedance to 50 W:
INPut:IMPedance 50
4. Set the input 1 signal lowpass filter state to On:
INPut:FILT ON
5. Set the input 1 to an expected peak-to-peak input voltage and an expected
input offset voltage:
INPut1:SETup 2,1
6. Set input 2 coupling to DC:
INPut2:COUPling DC
7. Set input 2 impedance to 50 W:
INPut2:IMPedance 50
8. Set the input 2 signal lowpass filter state to On:
INPut2:FILT ON
9. Set the Input 2 to an expected peak to peak input voltage and an expected
input offset voltage:
INPut2:SETup 2,1
10. Select the Time Interval with delay by time function:
SENSe[1,2]:FUNCtion "TINT:DEL:TIME"
NOTE. This command will not change most of the setup for the Counter. Input
coupling and impedance are not changed
11. Set the delay to 1 msec:
SENS:TINT:DELay: 1e-3
Programming Example