Yamaha ES6 Recording Equipment User Manual


 
About MIDI
183
Owner’s Manual
Basic Structure
Release Time (Control #072)
Messages which adjust the AEG release time set for each
Part.
The value set here is an offset value which will be added to or
subtracted from the voice data.
Attack Time (Control #073)
Messages which adjust the AEG attack time set for each Part.
The value set here is an offset value which will be added to or
subtracted from the voice data.
Brightness (Control #074)
Messages which adjust the filter cutoff frequency set for each
Part.
The value set here is an offset value which will be added to or
subtracted from the voice data. Lower values result in a softer
sound.
Depending on the voice, the effective range may be narrower
than the range available for adjustment.
Decay Time (Control #075)
Messages which adjust the AEG decay time set for each Part.
The value set here is an offset value which will be added to or
subtracted from the voice data.
Effect1 Depth (Reverb Send Level) (Control #091)
Messages which adjust the send level for the Reverb effect.
Effect3 Depth (Chorus Send Level) (Control #093)
Messages which adjust the send level for the Chorus effect.
Data Increment (Control #096)
Decrement (Control #097) for RPN
Messages which increase or decrease the MSB value of pitch
bend sensitivity, fine tune, or coarse tune in steps of 1. You will
need to assign one of those parameters using the RPN in the
external device in advance. The data byte is ignored. When
the maximum value or minimum value is reached, the value
will not be incremented or decremented further. (Incrementing
the fine tune will not cause the coarse tune to be
incremented.)
NRPN (Non-Registered Parameter Number)
LSB (Control #098) (Plug-in Board only)
NRPN (Non-Registered Parameter Number)
MSB (Control #099) (Plug-in Board only)
Messages which adjust a voice’s vibrato, filter, EG, drum
setup or other parameter settings.
First send the NRPN MSB and NRPN LSB to specify the
parameter which is to be controlled. Then use Data Entry
(page 182) to set the value of the specified parameter.
Note that once the NRPN has been set for a channel,
subsequent data entry will be recognized as the same
NRPN’s value change. Therefore, after you use the NRPN, you
should set a Null (7FH, 7FH) value to avoid unexpected
results.
For details, refer to the owner’s manual of the relevant Plug-in
Board.
RPN (Registered Parameter Number) LSB (Control #100)
RPN (Registered Parameter Number) MSB (Control #101)
Messages which offset, or add or subtract values from a
Part’s pitch bend sensitivity, tuning, or other parameter
settings. First send the RPN MSB and RPN LSB to specify the
parameter which is to be controlled. Then use Data
Increment/Decrement (page 183) to set the value of the
specified parameter. Note that once the RPN has been set for
a channel, subsequent data entry will be recognized as the
same RPN’s value change. Therefore after you use the RPN,
you should set a Null (7FH, 7FH) value to avoid unexpected
results.
The following RPN numbers can be received.
Channel Mode Messages
The following Channel Mode Messages can be received.
All Sounds Off (Control #120)
Clears all sounds currently sounding on the specified
channel. However, the status of channel messages such as
Note On and Hold On is maintained.
Reset All Controllers (Control #121)
The values of the following controllers will be reset to the
defaults.
All Notes Off (Control #123)
Clears all notes currently on for the specified channel.
However, if Hold1 or Sostenuto is on, notes will continue
sounding until these are turned off.
RPN MSB RPN LSB PARAMETER
00 00 Pitch Bend Sensitivity
00 01 Fine Tune
00 02 Coarse Tune
7F 7F Null
2nd BYTE 3rd BYTE MESSAGE
120 0 All Sounds Off
121 0 Reset All Controllers
123 0 All Notes Off
126 0 - 16 Mono
127 0 Poly
CONTROLLER VALUE
Pitch Bend Change 0 (center)
Aftertouch 0 (off)
Polyphonic
Aftertouch
0 (off)
Modulation 0 (off)
Expression 127 (max)
Hold1 0 (off)
Portamento 0 (off)
Sostenuto 0 (off)
Soft Pedal 0 (off)
Portamento Control Cancels the Portamento source key number
RPN Number not specified; internal data will not change
NRPN Number not specified; internal data will not change