Yamaha ES6 Recording Equipment User Manual


 
Setting Up
Resetting the User Memory to the Initial Factory Settings
44
Owner’s Manual
Resetting the User Memory to the Initial Factory Settings
The original factory setting of this synthesizer’s User Memory (page 186) can be restored as follows.
When the factory settings are restored, all the Voice, Performance, Song, Pattern, and system setting in the Utility mode you created will be erased.
Be sure to save all important data to SmartMedia or USB storage device before executing this procedure (pages 85, 91 and 131).
1 Press the [UTILITY] button to enter the Utility mode (the lamp lights).
2 Press the [JOB] button to enter the Utility Job mode.
3 Press the [ENTER] button. (The display prompts you for confirmation.)
n To cancel the Job, press the [DEC/NO] button.
4 Press the [INC/YES] button to execute the Job.
After the Job has been completed, a “Completed” message appears and operation returns to the original display.
An “Executing...” or “Please keep power on” message is shown when it takes a short amount of time to execute the Job. Never attempt to turn off the power
while data is being written to Flash ROM (while an “Executing...” or “Please keep power on” message is shown). Turning the power off in this state results
in loss of all user data and may cause the system to freeze (due to corruption of data in the Flash ROM). This means that this synthesizer may not be able
to start up properly, even when turning the power on next time.
n All settings in the Utility mode that are related to the Plug-in boards are stored only to the memory on those respective boards, and not to the User memory
of this synthesizer. Because of this, the Factory Set operation cannot be used to restore settings for those boards.