NEC NEAX 2000 Recording Equipment User Manual


 
FORCED ACCOUNT CODE
NEAX2000 IVS
2
Business/Hotel/Data Features and Specifications
NDA-24271, Issue 1.0
Page 173
FORCED ACCOUNT CODE
General Description
This feature forces the user to enter an Account Code (up to 8 or 10 digits) for all outgoing calls. The Account
Code must be dialed before dialing the outgoing number. Calls are processed only when the dialed Account
Codes are valid.
Station Application
All stations.
Operating Procedure
When dialing an outgoing call:
1. Lift the handset and receive dial tone.
2. Enter the Forced Account Code feature access code and receive service set tone.
3. Enter the Forced Account Code (up to 8 or 10 digits) and receive dial tone.
4. Dial the desired number.
Service Conditions
1. The maximum number of digits in the Forced Account Code is programmable, (for the entire system), from
1 to 8 or 10 digits.
2. The Forced Account Code access code can be 1 to 3 digits.
3. Forced Account Code Limitations
a. In the case of a system with AP01 card:
Number of digits: 1 digit-10 digits (If Check Code is provided, limited to 8 digits)
The same number of digits must be assigned to Authorization Code and Forced Account Code.
Number of codes: Up to 1,000 codes combined with Authorization Code and Direct Inward System
Access (DISA) Code.
b. In the case of a system without AP01 card:
Number of digits: 1 digit-8 digits
Number of codes: The maximum number of codes depends on the numbering scheme and digit
number. For details, refer to APPENDIX 3.
4. Both Authorization Code and Forced Account Code can be provided for the same system.
5. Stations are assigned this feature according to Class of Service programming in system data.
6. Forced Account Codes are recorded in the System Message Detail Records.
7. Existing restriction assignments will be applied even after a Forced Account Code is entered.
8. If the system is designated as KF registration, this feature is not available.
9. A Forced Account Code can be assigned per a station number so that one code is used only on the specific
station. Application Processor (AP01) is required.