NEC NEAX 2000 Recording Equipment User Manual


 
VARIABLE TIMING PARAMETERS
NEAX2000 IVS
2
Business/Hotel/Data Features and Specifications
NDA-24271, Issue 1.0
Page 327
VARIABLE TIMING PARAMETERS
General Description
This feature gives the system the versatility to change timing duration using the Maintenance Administration
Terminal (MAT) or the Customer Administration Terminal (CAT). All timing parameters are set initially in the
Resident System Program. These timing parameters can be changed according to the customer's requirements.
Station Application
Not applicable.
Operating Procedure
Refer to the Feature Programming Manual for programming instructions.
Service Conditions
The Feature Programming Manual contains instructions on how to change the following timing durations:
Parameter
Duration (in sec. unless otherwise marked)
Standard
Timing Variable Timing
Automatic Recall of Attendant transferred Camp-On
and unanswered calls
31.2 - 33.6
0.0 - 124.8 (2.4-sec. increments in 2.4 - 33.6 sec.
9.6-sec. increments in 28.8 - 124.8 sec.)
Elapsed time before Call Forwarding - No Answer
for incoming trunk calls or Attendant Overflow acti-
vation
32 - 36 0 - 120 (4-sec. increments)
Station Message Detail Recording (SMDR) valid
call timer
20 - 24 8 - 40
Disconnect recognition time for trunks 0.96 - 1.44 0 - 6.72 (0.48-sec. increments)
Recall timing for Exclusive Hold 236 - 240 0 - 396 (4-sec. increments)
Recall timing for Nonexclusive Hold and Call Park 60 - 64 0 - 396 (4-sec. increments)
Recall timing after station release for Call Transfer 24 - 28 0 - 120 (4-sec. increments)
Periodic Time Indication Tone interval 180 - 184 32 - 724 (60-sec. increments)
Automatic cancel time for unanswered external pag-
ing calls
300 60 - 900 (60-sec. increments)
Reorder tone timeout to enter Line Lockout state and
Off-Hook Alarm
28 - 32 4 - 32 (4-sec. increments)
Ringing duration of Automatic Wake Up call (Timed
Reminder)
28 - 32 0 - 32 (4-sec. increments)
Single digit dialing timer (Timing Start) 4 - 5 2 - 8 (1-sec. increments)
Maximum Automatic/Uniform Call Distribution
(ACD/UCD) call waiting time before answer or
abandonment for Peg Count
44 - 52 12 - 136 (4-sec. increments)
Automatic recall of Camp-On 24 - 32 8 - 128 (8-sec. increments)