NEC NEAX 2000 Recording Equipment User Manual


 
ATTENDANT CONSOLE
Pushbutton Calling Attendant Only
NEAX2000 IVS
2
Business/Hotel/Data Features and Specifications
NDA-24271, Issue 1.0
Page 39
6. The system operates only on a switched-loop basis. Fixed-loop operation is not available.
7. To place a multiple console system (or a multiple console tenant group) into Night Service, a prepro-
grammed master console must press the MODE, NITE and Answer key (press Night key for SN716
DESKCON). If one of the other consoles enters Night Service, all calls addressed to that console will be
directed to the other console(s).
8. When a console has entered Night Service, all calls already connected to its loop must be processed from
that console. Recalls and serial recalls are routed to the night transfer station, if assigned.
Pushbutton Calling Attendant Only
General Description
This feature permits an operator to place all calls over Dual-Tone, Multi-Frequency (DTMF) lines from the
push-button keypad on the Attendant Console.
Operating Procedure
The operator presses the push-button keypad to dial.
Service Conditions
1. This feature requires that all Central Office trunks or tie trunks accept push-button signaling (DTMF).
2. Push-button Calling- Attendant Only may be added to the system without providing push-button calling ca-
pability to other stations.
Serial Call
General Description
This feature is activated by the Attendant when an incoming calling party wishes to speak with more than one
internal party. When the internal station subsequently disconnects from the C.O. line call, the C.O. party auto-
matically rings back to the same Attendant.
Operating Procedure
1. The Attendant answers an incoming C.O. call.
2. The Attendant extends the call to the desired station.
3. The Attendant presses the SERIAL CALL SET (SC) key.
4. The called station and incoming caller are connected.
5. The called station hangs up. The Serial Call Termination (SRL) LED on the Attendant Console flashes at
60 IPM. If the Attendant is available, an audible indication is provided.
6. The Attendant presses the Answer or SRL key to return to the original incoming calling party.
Service Conditions
1. Serial Calling is not provided for Station-to-Station calling.
2. Serial Calling can be enabled or disabled on a per-console basis.