SINGLE DIGIT DIALING
NEAX2000 IVS
2
Business/Hotel/Data Features and Specifications
Page 286
NDA-24271, Issue 1.0
SINGLE DIGIT DIALING
General Description
This feature provides the station user the ability to dial single digit codes to access certain features while still
allowing the same digit dialed to be used as the first digit of guest room station numbers.
Station Application
All stations.
Operating Procedure
Normal call processing procedures apply.
Service Conditions
1. This feature is available on a numbering plan basis. Up to 4 different numbering plans are available per sys-
tem. For multiple tenant applications, each tenant can be assigned to one of these four numbering plans.
2. When this feature is assigned, digits in the numbering plan can overlap and Single Digit Dialing is based on
a timeout after dialing the first digit. The timing duration before the system stops looking for a second digit
is programmable from 2-8 seconds. The default setting is 4-5 seconds.
3. Digits 0-9, *, and # can be assigned within each numbering plan for Single Digit Dialing.
4. Single digit codes can be dialed with Consultation Hold.
5. Only the following features can be activated using Single Digit Dialing:
Trunk Answer Any Station
Trunk Access
Single Digit Station Numbering