NEC NEAX 2000 Recording Equipment User Manual


 
GROUP CALL
2 Way Calling
NEAX2000 IVS
2
Business/Hotel/Data Features and Specifications
Page 176
NDA-24271, Issue 1.0
Operating Procedure
To page stations of a group
1. Press the Speaker key or go off hook, and receive a dial tone.
2. Dial the access code, or press feature access key (Multiline Terminal only), for a desired paging group and
receive a ringback tone.
To answer the paging
1. The called terminals receive ringing. The LCD of the Multiline Terminal shows
PAGING
, including the sta-
tion number of the originator.
2. Answer the ringing page from the originator.
3. Paging stops after one of paged stations answer.
Service Conditions
1. A maximum of fifteen stations are paged simultaneously including the originator.
Even if more than fifteen stations are assigned to one group except the leader, the first fifteen stations are
paged in order of registered number on the system deta. Also one station can belong to multiple groups.
2. Single Line Telephones, Multiline Terminals, can be assigned as the stations within the group call groups
(Virtual line cannot be assigned). A station can belong to multiple groups.
3. Up to eight groups can be assigned as the call group by system data, including voice paging and Group Call-
Automatin Conference.
4. A Single Line Telephone, Multiline Terminal, can be an originator and page a group, even if the originator
does not belong to the group.
5. The originator cannot page two or more groups simultaneously.
A group cannot be paged simultaneously by the plural group call leaders.
6. If all stations within the paged group are busy, the originator hears a reorder tone.
The Group Call leader will continue to hear ringback tone until the page is answered. If does not time out.
7. A station can be paged in the idle state. When the station is busy at the time of paging, the station will not
be paged even if the station returns to idle afterward.
8. Even if a station sets Call Forwarding, the originator can page the station.