NEC NEAX 2000 Recording Equipment User Manual


 
NIGHT SERVICE
Day/Night Mode Change by Attendant Console
NEAX2000 IVS
2
Business/Hotel/Data Features and Specifications
NDA-24271, Issue 1.0
Page 235
Day/Night Mode Change by Attendant Console
General Description
This feature provides activation of DAY/NIGHT Mode Change by pressing a predetermined key from the At-
tendant Console.
Station Application
Attendant Console
Operating Procedure
To change Day to Night mode from SN610 Attendant Console
1. Dial the MODE feature access code or press the MODE key and the associated red LED lights. The LCD
displays
DAY
for day mode and the LED of the DAY key lights green.
2. Press the NIGHT key and the associated LED lights red. The LCD display changes from DAY to NIGHT.
3. Press the ANS key and receive service set tone. The LCD displays SET NIGHT. The mode of the console
is now changed from day to night mode.
4. Press the RLS key.
To change Night to Day mode from SN610 Attendant Console
1. Press the MODE key and the associated red LED lights.
2. Dial a predetermined password number which will display on the LCD.
3. Press the DAY key and the associated green LED lights. The LCD display changes from NIGHT to DAY.
4. Press the ANS key and receive service set tone. The LCD displays SET DAY. The mode of the console is
now changed from night to day.
5. Press the RLS key.
To change Day to Night mode from SN716 DESKCON
1. Press Night key. Night lamp will be lit.
To change Night to Day mode from SN716 DESKCON
1. Press Night key when Night lamp is lit. Night lamp will be off.
Service Conditions
1. This feature can be activated only by a master Attendant Console.
Day/Night Mode Change by Station Dialing
General Description
This feature allows selected stations to activate a change from day mode to night mode by dialing a special code.