General Description
Multiline Terminals are equipped with common Volume Control keys for:
Built-in Speaker / Handset Receiver Volume
Ring Volume
C.O. Transmission Level
LCD contrast
Ring Tone Frequency
The Volume Control keys are located on the lower front side of Multiline Terminals (UP
and DOWN
).
Station Application
All Multiline Terminals.
Operating Procedure
Built-in Speaker/Handset Receiver Volume
While in an off-hook state, press the
(UP) key to increase the volume, or the
(DOWN) key to decrease
the volume.
Ring Volume
1. Press the Feature key followed by 0: receive a test ring tone from the built in speaker.
2. Press the
(UP) key to increase the volume, or the
(DOWN) key to decrease the volume.
3. Press the Feature key, or lift the handset and restore the handset, to return to idle.
OR
When in a ringing state, press the
(UP) key to increase the volume, or the
(DOWN) key to decrease the
volume.
C.O. Transmission Level
While connected to a trunk, press the Feature key followed by 2 or 4:
Feature key + 2 : +5 dB (receiving) /+3dB (sending)
Feature key + 4 : +5 dB (receiving) /No gain (sending)
LCD contrast
While in an on-hook state, press the
(UP) key to decrease the contrast, or the
(DOWN) key to increase
the contrast.
Service Conditions
1. The Speaker/Handset volume control adjusts the volume of voice calls over the speaker/handset receiver,
and any tone sent by the system when using the speaker or handset.
2. The ring Volume Control adjusts the volume of all ring tones to the Multiline Terminal.