I/O PORTS S3C2410A
9-24
EXTINT2 Bit Description
FLTEN23 [31] Filter Enable for EINT23 0 = Disable 1= Enable
EINT23 [30:28] Set the signaling method of the EINT23.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
FLTEN22 [27] Filter Enable for EINT22 0 = Disable 1= Enable
EINT22 [26:24] Set the signaling method of the EINT22.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
FLTEN21 [23] Filter Enable for EINT21 0 = Disable 1= Enable
EINT21 [22:20] Set the signaling method of the EINT21.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
FLTEN20 [19] Filter Enable for EINT20 0 = Disable 1= Enable
EINT20 [18:16] Set the signaling method of the EINT20.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
FLTEN19 [15] Filter Enable for EINT19 0 = Disable 1= Enable
EINT19 [14:12] Set the signaling method of the EINT19.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
FLTEN18 [11] Filter Enable for EINT18 0 = Disable 1= Enable
EINT18 [10:8] Set the signaling method of the EINT18.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
FLTEN17 [7] Filter Enable for EINT17 0 = Disable 1= Enable
EINT17 [6:4] Set the signaling method of the EINT17.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered
FLTEN16 [3] Filter Enable for EINT16 0 = Disable 1= Enable
EINT16 [2:0] Set the signaling method of the EINT16.
000 = Low level 001 = High level 01x = Falling edge triggered
10x = Rising edge triggered 11x = Both edge triggered