Samsung S3C2410A Microphone User Manual


 
S3C2410A ELECTRICAL DATA
24-35
Table 24-13. IIC BUS Controller Module Signal Timing
(V
DD
= 1.8V ± 0.15 / 2.0 V ± 0.1 V, T
A
= -40 to 85 °C, V
EXT
= 3.3V ± 0.3V)
Parameter Symbol Min Typ. Max Unit
SCL clock frequency f
SCL
std. 100
fast 400
kHz
SCL high level pulse width t
SCLHIGH
std. 4.0
fast 0.6
µ
s
SCL low level pulse width t
SCLLOW
std. 4.7
fast 1.3
µ
s
Bus free time between STOP and START t
BUF
std. 4.7
fast 1.3
µ
s
START hold time t
STARTS
std. 4.0
fast 0.6
µ
s
SDA hold time t
SDAH
std. 0
fast 0
std. - fast
0.9
µ
s
SDA setup time t
SDAS
std. 250
fast 100
ns
STOP setup time t
STOPH
std. 4.0
fast 0.6
µ
s
NOTES: Std. means Standard Mode and fast means Fast Mode.
1. The IIC data hold time(tSDAH) is minimum 0ns.
(IIC data hold time is minimum 0ns for standard/fast bus mode in IIC specification v2.1.)
Please check the data hold time of your IIC device if it's 0 nS or not.
2. The IIC controller supports only IIC bus device(standard/fast bus mode), not C bus device.
Table 24-14. SD/MMC Interface Transmit/Receive Timing Constants
(V
DD
= 1.8V ± 0.15 / 2.0 V ± 0.1 V, T
A
= -40 to 85 °C, V
EXT
= 3.3V ± 0.3V)
Parameter Symbol Min Typ. Max Unit
SD Command output Delay time t
SDCD
0.5 1.3 ns
SD Command input Setup time t
SDCS
5.8 15.2 / 14.2 ns
SD Command input Hold time t
SDCH
- 0.1 ns
SD Data output Delay time t
SDDD
0.3 0.6 ns
SD Data input Setup time t
SDDS
6.3 15.3 / 14.3 ns
SD Data input Hold time t
SDDH
- 0.1 ns