KARMA GE guide
908
Template Steps 13…16
Same as above, except for steps 13–16.
Note that if the number of steps in the Phase Pattern
(Pattern Items) is less than the steps for which
Templates are being changed, these will produce no
audible results.
Step Transpose Value [–48…0…+48]
Allows a separate Transpose Value to be used in each
step of the Phase Pattern (-48…+48 semitones) that
affects all notes that are generated during that step.
The Step Transpose Value is cumulative with the Phase
Transpose Value discussed below. For example, if a
Step Transpose Value is -12, and the Phase Transpose
Value for the Phase in use during that step is +24, the
overall transpose would be +12. While this value is not
directly accessible in each Phase Pattern Step as a GE
RT Parameter, it may be set as part of a GE and varied
by the following two GE RT Parameters:
Step Transpose On/Off [0, 1]
Allows the effect of the Step Transpose Values in each
Phase Pattern Step to be turned on or off for the entire
Phase Pattern.
Step Transp. Template [0…17]
Allows one of 18 different templates for the 16 steps of
a Phase Pattern to be chosen and applied to the current
Phase Pattern. These 18 templates provide a wide
variety of switching between octaves in various orders
and amounts, and correspond to various settings of the
Triton Arpeggiator “Octave” and “Octave Motion”
parameters (refer to table at the bottom). They can be
used to simulate Triton Arpeggio performances, in
addition to other useful applications.
Template for emulating the operation of the TRITON series arpeggiator parameters “Octave” and “Octave Motion”
0: Off 1: On